We now have a great option for people looking for a digital snake solution, our SB168 ES. The product has 16 inputs and 8 output in a 3 rack space box. The system is based on the EtherSound Technology, high-quality bidirectional multi-channel transmission capabilities, and its use of easily obtainable CAT5e cable. From there you just need to have the MY16-ES64 and MY16- EX mini-YGDAI cards to connect to a Yamaha digital console.

Well enough for now, how about if you look for us at AES?
We will be there presenting our new family member.
Hope to see you there.

Thursday, August 28, 2008

+48V doesn't work?

"+48V" of the input channel is turned on but its phantom power is not provided to my condenser microphone.

Please make sure Phantom Master switch is turned on.
(PM1D)

Front panel of AI8
(PM5D-RH)

Rear panel of PM5D-RH
* PM5D doesn't have master switch

(DSP5D)

Mixer Setup screen

(M7CL)

Setup screen

(LS9)

System Setup screen

Friday, August 22, 2008

Assign a static IP address to your PC

Which is better to assign an IP address to my PC, automatic (DHCP) or static?

We recommend to assign a static IP address to your PC.
Automatic assignment from your network's DHCP server is very convenient, but usually the server update the assigned IP address every few hours and it would reset Studio Manager or DME Designer connection.
Windows XP
1 Select [Start] → [Control Panel].
The “Control Panel” is displayed.
2 If the “Control Panel” is in Category display, click [Switch to Classic View].
3 Double-click [Network Connections] → [Local Area Connection].
The “Local Area Connection Status” dialog box will be displayed.
4 Click [Properties] on the [General] tab.
The “Local Area Connection Properties” dialog box will be displayed.
5 Select [Internet Protocol (TCP/IP)] on the [General] tab, then click [Properties].
The “Internet Protocol (TCP/IP) Properties” dialog box will be displayed.
6 Click [Use the following IP address] on the [General] tab.
7 Enter your computer’s IP address into [IP address]***Do not use the same number as the console***, (i.e., 192.168.0.130), the Gateway’s IP address into [Default gateway], and “255.255.255.0” into [Subnet mask].
* When installing on the same subnet as the DME unit(s), set the gateway’s host address to 254.
8 Click [OK].
9 Restart your computer.

Thursday, August 21, 2008

Why is my console locked to 96kHz?

My PM5D is receiving digital audio via MY-slot and locking its word clock to the slot. The incoming digital audio is 48k but the console is locked to 96k. How do I change it to 48k?

Please go to Word Clock screen and select the MY-slot as a clock source. Then, change its Input/Output Format of the slot from "DOUBLE CHANNEL" to "DOUBLE SPEED". In a few seconds, the console will be locked to 48k.

All 96k capable products, such as DM/0 series, DME series, and PM5D, may have this issue.

Wednesday, August 20, 2008

STEREO/MONO link - LS9

Do I need to go to the Master Layer to change my MONO output level?

Yes, you do.
The MONO master fader is on the Master layer and the Custom Fader layer when you assign the fader to it.

By the way, there is a preference for linking the MONO and the STEREO master faders.
If those levels are always controlled together, you can turn the preference on. By using digital attenuator in the EQ of the MONO or the STEREO master channel, you can change balance between those channels anytime.

(LS9 Owner's Manual, p.195)
"This specifies whether STEREO channel and MONO channel on/off and fader operations will be linked.
If you turn this button on, the STEREO channel on/off setting will be copied to the MONO channel, and subsequently on/off operations will be linked. Faders will be linked while preserving the difference in level."